From my unit I can only get the graph to do co2 and nothing else, maybe some marketing person made graphics that aren’t accurate, because I do recall seeing that image too, but didn’t know what it was of and assumed it was co2. But the actual unit has no way of making a graph of the spo2 as far as I can tell, certainly not mentioned in the manual that you can. It just does the spo2 % number like shown on the screen.
I’m familiar with the CapnoTrainer there are lots of good videos out there describing what they do in detail many created by the founder I think. They are what convinced me that I probably have a problem that is unique enough that it’s probably not wise to pay for their expensive service. Could have sworn it was around $2k for rental for like a month and a person helping you for a few hours because the rate for the person is around $250 an hour and contributes more to the cost than the rental. I can change the way I breath in various ways, but it makes things worse because my nervous system seems to force itself back into the old pattern and that process is always brutal on my body as it gets much worse as it finds it way back to the old way.
I had a couple instances that suggest what is stuck in my body is very much like trauma energy. I found by accident various ways to manipulate my breath that the later had the effect when I laid down it would feel like the energy from the tension in my abdomen was slowly moving to my arms, legs, and jaw/face over several minutes to 30+ minutes. I’d end up buzzzing with intense energy and feel locked down in those areas at the same time. It would feel like what I’ve experienced if in a life threatening situation and the body mounted intense energy to defend itself and then at the same time froze because it realized it was too dangerous to fight. If the energy can pass through my body then the symptoms will probably stop. Haven’t been able to figure out how to get it to happen, if I move especially early on when the energy just starts moving it hides again.
Not sure if I get what you are saying clearly, you already had rented one? and are going to do it again?
I had a couple more questions about the CONTEC device:
What’s the lag time from when you breathe to when the waveform is displayed on the screen, and when the number updates?
How does it prevent water (from exhaled air) from getting into the device? The CapnoTrainer uses water traps inserted between the cannula and the device itself, and these water traps need to be replaced every once in a while. But I haven’t seen anything similar for the CONTEC device.
It can seem real time, but if I do an experiment such as breath hold or other big breathing change and wait till I see it, it’s about 5 seconds from memory.
They remove the water, using that gold color threaded thingy in the tube it attracts the water vapor and releases it out of the tube, but not perfectly, when I stop if there is still water in the tube—which is very often especially if used in the Winter with low humidity, I leave the machine running without me being plugged into it from 5-30 minutes depending on how much water was in the tube to help clear it because without the airflow it won’t clear out.
I also figured out you can reuse the water filters by just ripping the ends off the tube they are just forced onto a tight connection. Then you can have cheaper cannulas without it and cut a spot on those and force it back on. It works better than expected because water filters are not permanently attached its just by tightness of the connection. Then if you throw out a cannula for sanitary reasons you can just take out the water filter and use it with another new one, I also experimented with attaching two of them on one cannula to make the filter even more powerful and it seems to work without messing up the readings as far as I can tell. Not sure if it actually works better, but I use it that way now.
If you end up buying it and the cannulas to get the best price look on that site, ebay, and aliexpress and buy whatever has the best price. I can also probably sell you some tubes with and without filters if you want them for really low cost way below what they sell them at because I bought way too many, though they are probably close to expired based upon the date they put on them—can tell you the exact date if you want to know.
I only used the ones from contec and looked for other options but it was hard figuring out which would fit and eventually gave up on trying to find cheaper ones, other than if you can find a page that sells them in larger quantities they then end up less per unit. Also the ones from contec are no smells at all, I did buy some on amazon that I thought could work and they didn’t plus they smelled really bad because the type of plastic. So the contec ones are at least of good quality material
I found someone in my local area who has a CapnoTrainer and was willing to rent it out to me and coach me, so it was a lot cheaper than the official route. But yeah, in general rentals are quite expensive unfortunately. If I couldn’t find anyone who would rent one out to me for a reasonable price, I would probably have just gone with the CONTEC device as you did.
When I originally wrote this LW post, I had never used a capnometer of any kind (it just seemed quite promising and I was confused why basically no one was talking about it). After writing the post, I found someone who would rent a CapnoTrainer to me, and have been using the device now for about a week. The CapnoTrainer is still the only capnometer I have used. It’s still too early for me to say whether the device “worked” or not, but so far it’s been a quite promising experience (I’m planning to write more in maybe a month when the rental period ends).
Also going to add the ones I bought on amazon that didn’t work were much thicker than the contec ones, the connector did work though, but I think the thickness of the space in the tubing may need to be the same perhaps to work, and the contec ones are very narrow. Thicker ones are probably for oxygen delivery and other uses and not co2 reading.
Hi, I wanted to give an update. Capnometry biofeedback worked better than I expected. My baseline ET CO2 went from around 27mmHg to around 40mmHg in the first 1.5 weeks of using the device, and stayed there for the whole month I had access to the device. (I’ve now returned the device.) The key thing I discovered was that even though I was already nasal breathing 99.9% of the time, my nasal breaths were still quite audible and so I was overbreathing because of that. The biofeedback+coaching allowed me to switch my breathing to a silent nasal one in stages. I still experience air hunger, but it is a lot more subtle than before. I still have trouble talking, some of the time (I think talking makes me overbreathe, so if I start out with no air hunger then I can talk for quite a while, but if I start talking when I already have some air hunger, then I quickly reach my limits). I still on occasion mysteriously have a lot more air hunger than normal and feel like I “forgot how to breathe”, and I wonder if that means I have some sort of autonomic problem… I’ve been writing up a lot of my thoughts here. I might retry capnometers in a few months or a year or something, but for now my plan is to go back to (original Russian-lineage) Buteyko method and really logging the time (rather than half-assing it, which is what I was doing previously with Buteyko). Feel free to ask any questions.
From my unit I can only get the graph to do co2 and nothing else, maybe some marketing person made graphics that aren’t accurate, because I do recall seeing that image too, but didn’t know what it was of and assumed it was co2. But the actual unit has no way of making a graph of the spo2 as far as I can tell, certainly not mentioned in the manual that you can. It just does the spo2 % number like shown on the screen.
I’m familiar with the CapnoTrainer there are lots of good videos out there describing what they do in detail many created by the founder I think. They are what convinced me that I probably have a problem that is unique enough that it’s probably not wise to pay for their expensive service. Could have sworn it was around $2k for rental for like a month and a person helping you for a few hours because the rate for the person is around $250 an hour and contributes more to the cost than the rental. I can change the way I breath in various ways, but it makes things worse because my nervous system seems to force itself back into the old pattern and that process is always brutal on my body as it gets much worse as it finds it way back to the old way.
I had a couple instances that suggest what is stuck in my body is very much like trauma energy. I found by accident various ways to manipulate my breath that the later had the effect when I laid down it would feel like the energy from the tension in my abdomen was slowly moving to my arms, legs, and jaw/face over several minutes to 30+ minutes. I’d end up buzzzing with intense energy and feel locked down in those areas at the same time. It would feel like what I’ve experienced if in a life threatening situation and the body mounted intense energy to defend itself and then at the same time froze because it realized it was too dangerous to fight. If the energy can pass through my body then the symptoms will probably stop. Haven’t been able to figure out how to get it to happen, if I move especially early on when the energy just starts moving it hides again.
Not sure if I get what you are saying clearly, you already had rented one? and are going to do it again?
I had a couple more questions about the CONTEC device:
What’s the lag time from when you breathe to when the waveform is displayed on the screen, and when the number updates?
How does it prevent water (from exhaled air) from getting into the device? The CapnoTrainer uses water traps inserted between the cannula and the device itself, and these water traps need to be replaced every once in a while. But I haven’t seen anything similar for the CONTEC device.
It can seem real time, but if I do an experiment such as breath hold or other big breathing change and wait till I see it, it’s about 5 seconds from memory.
For the water I use these types of tubes: https://contechealth.com/collections/hot-sales/products/tube-adapter-for-co2-module-etco2-capnograph-respiratory-cable-for-cms8000-vet-veterinary?_pos=3&_sid=3eab643da&_ss=r
They remove the water, using that gold color threaded thingy in the tube it attracts the water vapor and releases it out of the tube, but not perfectly, when I stop if there is still water in the tube—which is very often especially if used in the Winter with low humidity, I leave the machine running without me being plugged into it from 5-30 minutes depending on how much water was in the tube to help clear it because without the airflow it won’t clear out.
I also figured out you can reuse the water filters by just ripping the ends off the tube they are just forced onto a tight connection. Then you can have cheaper cannulas without it and cut a spot on those and force it back on. It works better than expected because water filters are not permanently attached its just by tightness of the connection. Then if you throw out a cannula for sanitary reasons you can just take out the water filter and use it with another new one, I also experimented with attaching two of them on one cannula to make the filter even more powerful and it seems to work without messing up the readings as far as I can tell. Not sure if it actually works better, but I use it that way now.
If you end up buying it and the cannulas to get the best price look on that site, ebay, and aliexpress and buy whatever has the best price. I can also probably sell you some tubes with and without filters if you want them for really low cost way below what they sell them at because I bought way too many, though they are probably close to expired based upon the date they put on them—can tell you the exact date if you want to know.
I only used the ones from contec and looked for other options but it was hard figuring out which would fit and eventually gave up on trying to find cheaper ones, other than if you can find a page that sells them in larger quantities they then end up less per unit. Also the ones from contec are no smells at all, I did buy some on amazon that I thought could work and they didn’t plus they smelled really bad because the type of plastic. So the contec ones are at least of good quality material
Thank you, this is helpful!
I found someone in my local area who has a CapnoTrainer and was willing to rent it out to me and coach me, so it was a lot cheaper than the official route. But yeah, in general rentals are quite expensive unfortunately. If I couldn’t find anyone who would rent one out to me for a reasonable price, I would probably have just gone with the CONTEC device as you did.
When I originally wrote this LW post, I had never used a capnometer of any kind (it just seemed quite promising and I was confused why basically no one was talking about it). After writing the post, I found someone who would rent a CapnoTrainer to me, and have been using the device now for about a week. The CapnoTrainer is still the only capnometer I have used. It’s still too early for me to say whether the device “worked” or not, but so far it’s been a quite promising experience (I’m planning to write more in maybe a month when the rental period ends).
Also going to add the ones I bought on amazon that didn’t work were much thicker than the contec ones, the connector did work though, but I think the thickness of the space in the tubing may need to be the same perhaps to work, and the contec ones are very narrow. Thicker ones are probably for oxygen delivery and other uses and not co2 reading.
Hi, I wanted to give an update. Capnometry biofeedback worked better than I expected. My baseline ET CO2 went from around 27mmHg to around 40mmHg in the first 1.5 weeks of using the device, and stayed there for the whole month I had access to the device. (I’ve now returned the device.) The key thing I discovered was that even though I was already nasal breathing 99.9% of the time, my nasal breaths were still quite audible and so I was overbreathing because of that. The biofeedback+coaching allowed me to switch my breathing to a silent nasal one in stages. I still experience air hunger, but it is a lot more subtle than before. I still have trouble talking, some of the time (I think talking makes me overbreathe, so if I start out with no air hunger then I can talk for quite a while, but if I start talking when I already have some air hunger, then I quickly reach my limits). I still on occasion mysteriously have a lot more air hunger than normal and feel like I “forgot how to breathe”, and I wonder if that means I have some sort of autonomic problem… I’ve been writing up a lot of my thoughts here. I might retry capnometers in a few months or a year or something, but for now my plan is to go back to (original Russian-lineage) Buteyko method and really logging the time (rather than half-assing it, which is what I was doing previously with Buteyko). Feel free to ask any questions.